Portable power station sizing for camping: watt hours first, watts second
The biggest number on a portable power station box is the one most likely to mislead you. Shoppers read 1,800 watts and picture hours of power. Watts say nothing about hours. Watts are how hard the station can pull at one moment. Watt hours are how much energy is actually in the tank. Size a station for camping in the wrong order, watts first, and you can buy a unit that runs a kettle beautifully and still goes dark before the fridge has finished its first night.
The job, in one paragraph
Difficulty: easy, with a pen. Time: about 20 minutes at the kitchen table. Cost: nothing to do the math; the station itself is the purchase this math protects. The stop line: if the load list includes medical equipment, size it from that device's own manual, add a wider margin than this guide uses, and run the full setup at home for a night before trusting it at a campsite. Everything else on a normal camping list is a comfort load, and comfort loads can be estimated honestly with the procedure below.
The load list comes before the shopping
Tools and materials for this job are a pen, the nameplates on your own gear, and one rule: the wattage figure to use is the one stamped on the bottom or back of the appliance, or on its nameplate, which is where the US Department of Energy tells readers to find it. Marketing pages round. Nameplates do not care about marketing.
- Every device you honestly expect to plug in, listed without optimism.
- Its nameplate watts, copied exactly.
- The hours per day it will actually run, which for a fridge is not 24.
- One line left blank for the device somebody adds in the driveway.
The fridge line deserves its own warning before any arithmetic. A compressor fridge cycles. The Department of Energy's method for estimating a refrigerator's time at maximum wattage is to divide the total plugged in time by three. A fridge plugged in for 24 hours is estimated at 8 hours of full draw. Skip that correction and the fridge alone can push you one size class too high.
The sizing procedure, step by step
- Write watts times hours for every load. The Department of Energy formula is wattage multiplied by hours used per day, divided by 1,000, giving daily kilowatt hours. Multiply back up and the same arithmetic gives watt hours directly. A lantern at 10 watts for 5 hours is 50 watt hours. A laptop at 60 watts for 3 hours is 180 watt hours.
- Apply the duty cycle to anything that cycles. A 12 volt fridge with a 60 watt nameplate, plugged in for 24 hours, counts as roughly 8 hours at full draw by the Energy method: 480 watt hours, not 1,440.
- Add the small loads honestly. Two phone charges at an assumed 15 watt hours each add 30 watt hours. State assumptions like that one as assumptions. They are planning figures, not measurements of your phone.
- Total the day. The worked list for a two person car camping weekend, one day of it: lantern 50, laptop 180, fridge 480, phones 30. Total: 740 watt hours per day.
- Gross up for losses and reserve. Sizing guidance adds roughly 15 percent for inverter inefficiency when battery power is converted to household AC, and roughly 20 percent of reserve so the battery is not drained to empty. Applied in sequence, 740 watt hours becomes about 1,020 watt hours of rated capacity. That is the buyable number.
- Check simultaneous watts last. Add the watts of everything that could run at the same moment. Fridge 60, laptop 60, lantern 10, phone charging 30: about 160 watts, a light load. Now swap in a 1,500 watt kettle as an example load. The energy cost of one boil is modest, but no station with a 300 watt output will run it at all, whatever its battery size.
What success looks like: a written daily total in watt hours, a grossed up rated capacity to shop against, and a simultaneous watt figure that the chosen station's continuous output clears with room to spare. If any of the three numbers is missing, the purchase is a guess.
Three spec sheets against the worked answer
The worked load asks for about 1,020 watt hours of rated capacity and very little simultaneous power. Checked against manufacturer specifications, the classes separate cleanly:
| Station | Capacity | AC output, continuous | Surge | Weight | Expansion |
|---|---|---|---|---|---|
| Jackery Explorer 300 Plus | 288 Wh | 300W | 600W | 3.75 kg | None listed on the spec page |
| EcoFlow DELTA 2 | 1,024 Wh | 1,800W | 2,700W | About 12 kg | To 2,048 Wh or 3,040 Wh with an extra battery |
| Anker SOLIX C1000 | 1,056 Wh | 1,800W | 2,400W | 12.9 kg | To 2,112 Wh with an expansion battery |
Specifications from the manufacturers' own pages, checked 3 November 2026. All three use LiFePO4 batteries. One caution the spec sheets themselves supply: Jackery Canada lists the Explorer 300 Plus as discontinued and points buyers to a newer model, while other regional stores still present it as current. Model names in this category churn fast, so buy against the numbers, not the name.
The verdict on the worked load is plain. The small station is a fine phone and lights unit at 3.75 kg, and it fails this load list by a factor of three and a half on capacity alone. Either 1,000 watt hour class station covers the day as calculated, with output to spare for a heavier simultaneous load, and either one asks you to carry roughly 12 to 13 kg from car to picnic table. On a walk in site, that weight line is a real part of the spec sheet, not a footnote. Drop the fridge from the load list and the small class wins the same arithmetic just as cleanly, which is the point of doing the math before the shopping: the load decides, the badge does not.
The three ways this purchase goes wrong
Buying by watts. A shopper compares 300W against 1,800W, assumes the bigger number runs things longer, and never reads the watt hour line at all. Fix: capacity first, output second, in that order, every time.
Counting the fridge at 24 hours. The nameplate watts multiplied by a full day triples the fridge's real share and inflates the whole purchase. Fix: the divide by three duty cycle estimate in step two, then a margin from the reserve, not from a second exaggeration.
Draining to empty on paper. A load list that exactly equals the rated capacity works only in a spreadsheet. In a tent it ends with a dark station on the second evening. Fix: the 20 percent reserve in step five is not padding for the retailer's benefit. It is the difference between a plan and a hope.
, Tom Reilly, Home & DIY Writer